SÜPERHEAT, SUPCOOLİNG UYGULAMA: Yüksek verim - Es-kon

advertisement
• SÜPERHEAT, SUPCOOLİNG UYGULAMA:
Yüksek verim yüksek COP (A SINIFI CİHAZ)
• SUPERHEAT,SUPCOOLING APPLICATION:
High efficiency, high COP (A -class device)
• ÇEVRECİ SOĞUTUCU GAZ: R407C , R410A, 314
a kulllanılmaktadır. Düşük karbon salınımı ozana
zarar vermez.
• ENVIRONMENT REFRIGERANT: R407C , R410A
, is a 314 ‘s used . Low carbon emissions will not
harm the Ozone.
• HEAT PUMP ÇALIŞMA: İstenirse Kış aylarında
Heat pump dizaynı ile ısıtma yapar.Heat pump
oldukça verimli ve düşük işletme gideri sağlar.
Dış hava sıcaklığına göre defrost uygulaması kış
çalışmasının güvencesidir.
• HEAT PUMP OPERATION: If prompted, provide
heating with heat pump in winter. Heat pump is
highly efficient and low operating costs .Defrost
according to the outside temperature is the
assurance of winter operation.
• SOĞUTMA DEVRE VE KORUMA ELEMANLARI:
Sadece soğutma: Likit hattı stop vana ,emiş hattı
stop vanası, gözetleme camı, filtre drayer, switch,
emiş hattı akümülatörü, termostatik expancion,
resetsiz yüksek basınç bulunmaktadır. Heat pump
cihazlarda ayrıca; Dört yollu vana, çek valf, defrost
sistemi mevcuttur. Kompresör yüksek basınç
koruması, kompresör düşük basınç koruması,
kompresör arıza koruması, kompresör aşırı yük
koruması, kondenser fan aşırı yük veya aşırı ısınma
koruması, faz sırası ve faz koruması ve hava akışı
kesme koruması bulunmaktadır.
• COOLING CIRCUIT AND PROTECTION
COMPONENTS:
• İSTEĞE GÖRE: Fan hız kontrolü ve
kompresörlerde inverter çalışma sağlanır.
• HAVA SOĞUTMALI KONDENSER (Hava
soğutmalı modellerde): Bakır boru üzerine
alüminyum kanatların uygun hatve ile dizilip bakır
boruların alüminyum kanatlara özel yöntemlerle
şişirilmesi ile yüksek ısı transferi sağlar.
• AXİAL FAN: External tip, sessiz 6 kutuplu düşük
gürültülü IP 54 , fan koruyucu ızgaraya sahiptir.
Kontrol isteğe göre Dijital mikroproresör kontrol
ile tüm değerler izlenir ve kontrol edilir. Arızalar
kolayca belirlenir.
ONLY COOLING:
Contains liquid line stop valve, suction line stop
valve , sight glass, filter drier , switches, suction
line accumulator , thermostatic expancion,
high pressure without reset. In addition heat
pump unit contains four -way valve , check
valve, defrost system, Compressor high pressure
protection, compressor low pressure protection,
compressor failure protection, compressor
overload protection , condenser fan overload or
overheating protection , phase sequence , phase
protection and air flow shutdown protection .
• OPTIONAL : Fan speed control and compressor
inverter operation can be provided.
• AIR COOLED CONDENSER(FOR AIRCOOLED
MODELS): Copper pipes line up of aluminum
fins on copper aluminum pipe with suitable pitch
blades. This provides high heat transfer to be
inflated with special methods.
• AXİAL FAN: External type, quiet 6-pole, lownoise IP 54,has Fan protection grid, optionally
a microprocessor based digital control , all
parameters can be monitored and controlled.
Faults can be easily observed.
• ПРИМЕНЕНИЕ ПЕРЕГРЕВА,
ПЕРЕОХЛАЖДЕНИЯ: Высокая эффективность,
высокий КПД (ПРИБОР КЛАССА A)
• ЭКОЛОГИЧНЫЕ ХЛАДАГЕНТЫ: используются
R407C, R410A, 314a. Низкий уровень выбросов
углерода не наносит вреда озону.
• РАБОТА ТЕПЛОВОГО НАСОСА: в зимние
месяцы конструкцией теплового насоса
может осуществляться отопление. Тепловой
насос обеспечивает довольно продуктивное
отопление и низкие эксплуатационные расходы.
Применение в зависимости от температуры
воздуха на улице системы defrost гарантирует
работу в зимний период.
• ЭЛЕМЕНТЫ СХЕМЫ И ЗАЩИТЫ
ОХЛАЖДЕНИЯ: только охлаждение: имеются
запорный клапан линии жидкости, запорный
клапан всасывающей линии, смотровое стекло,
фильтр, осушитель, переключатель, аккумулятор
всасывающей линии, терморегулятор, сброс
высокого давления без перезагрузки. Также
в устройствах теплового насоса имеются:
четырехканальный клапан, обратный
клапан, система defrost. Имеются защита
компрессора от высокого давления, защита
компрессора от низкого давления, аварийная
защита компрессора, защита компрессора от
перегрузки, защита вентилятора конденсатора
от перегрузки или перегрева, защита
последовательности фаз и защита фаз, а также
защита от прерывания потока воздуха.
• ОПЦИОНАЛЬНО: обеспечивается регулировка
скорости вращения вентилятора и инверторный
режим работы в компрессорах.
• КОНДЕНСАТОР НА ВОЗДУШНОМ
ОХЛАЖДЕНИИ (в моделях с воздушным
охлаждением): алюминиевые ребра на
медных трубах выстроены с соответствующим
интервалом, после чего медные трубы
раздувают специальным способом на
алюминиевые ребра, что обеспечивает высокую
теплоотдачу.
• ОСЕВОЙ ВЕНТИЛЯТОР: наружного типа,
беззвучный с 6 полюсами, с низким уровнем
шума IP 54, имеется защитная решетка
лопастей. Контроль: опционально. С помощью
микропроцессора контроля отслеживаются
и контролируются все значения. Легко
определяются неисправности.